Mini Toroidal PCB Mounted Current Transformers

The TA series of toroidal, solid core current transformers provide a highly accurate and cost effective sensor for measuring AC electric current. The TA series converts the primary AC current signal to a level suitable for micro-processor based electronic assemblies. The pin-in-hole (PIH) PCB mounted current transformers feature asymmetrical mounting in a compact design. Incorporated into products designed for electric power measurement, electric power quality monitoring, Supervisory Control and Data Acquisition (SCADA), the TA series offer superior accuracy and linearity.

Features:
TA ModelsRated PrimarySpecifications
TV31B
(Data Sheet – 544kb)
1mA, 2mA
  • AC current style transformer for AC voltage measurement
  • Ratio: 1:1
  • Accuracy: Class 0.1, 0.2
  • UL Certified (File #E466650)
TA21B11
PCB mounted or lead wires
(Data Sheet – 328kb)
5A(20A), 5A(50A), 5A(60A), 10A(40A)
rated input (maximum current)
  • Ratio: 1:1000, 1:2000, 1:2500
  • Accuracy: Class 0.1, 0.2
  • Opening: 6.7mm
  • Secondary Impedance: ≤ 40Ω
TA21CM
PCB mounted
(Data Sheet – 1Mb)
5A to 15A
rated input
  • Ratio: 1:1000, 1:2000, 1:2500
  • Accuracy: Class 0.2, 0.5
  • Opening: 4.8mm
  • Secondary Impedance: ≤ 50Ω
TA22B11
PCB mounted or lead wires
(Data Sheet – 310kb)
5A(20A), 5A(50A), 10A(40A), 20A(80A)
rated input (maximum current)
  • Ratio: 1:1000, 1:2000, 1:2500
  • Accuracy: Class 0.1, 0.2
  • Opening: 8.7mm
  • Secondary Impedance: ≤ 50Ω
TA22D11
PCB mounted or lead wires
(Data Sheet – 607kb)
5A(50A), 10A(40A), 10A(60A), 20A(80A)
rated input (maximum current)
  • Ratio: 1:1000, 1:2000, 1:2500
  • Accuracy: Class 0.1, 0.2
  • Opening: 8.0mm
  • Secondary Impedance: ≤ 50Ω
TA22E11
PCB mounted or lead wires
(Data Sheet – 349kb)
5A(50A), 10A(60A), 10A(100A), 20A(120A)
rated input (maximum current)
  • Ratio: 1:1000, 1:2000, 1:2500
  • Accuracy: Class 0.1, 0.2
  • Opening: 12.8mm
  • Secondary Impedance: ≤ 50Ω
  • UL Certified (File #E466650)
TA2011
Lead wires
(Data Sheet – 297kb)
5A(20A), 5A(50A), 10A(40A), 15A(60A)
rated input (maximum current)
  • Ratio: 1:1000, 1:1500, 1:2000
  • Accuracy: Class 0.1, 0.2
  • Opening: 8.0mm
  • Secondary Impedance: ≤ 20Ω